πŸ“žCall: +63 966 310 3479

Genuine Component Replacement β€’ Makati & Taguig

Expert Aircon Unit Parts Replacement in Makati & Taguig

When a single internal component fails, your entire aircon unit stops working β€” but that doesn’t mean you need to buy an expensive new aircon.

Sterling Air pinpoint-diagnoses broken parts, sources factory-matched OEM components for all major brands, and executes precise on-site replacements across Makati, BGC, and Taguig.

Component Failure Diagnostics

Don’t replace the entire unit for a single failed part. Match your symptom below.

Unit Runs But Gives Zero Cooling

The compressor’s internal electrical windings or valves may have failed. We perform winding resistance tests before recommending a matched compressor replacement.

Clicking Sounds & Motor Stalling

A weakened starting capacitor prevents the compressor or fan motor from kicking in. We test microfarad ratings and swap blown capacitors on the spot.

Error Codes & Remote Unresponsiveness

Voltage spikes or moisture cause PCB control board failures. We test circuit traces to repair or swap damaged microprocessor PCB modules.

Weak Airflow or Screeching Sounds

Dry bearings or burnt motor windings impair fan blades. We replace indoor blower motors or outdoor condenser motors with exact RPM spec matches.

Water Pooling Under Indoor Unit

In high-rise condos, automatic condensate drain pumps fail over time. We replace faulty pumps to ensure continuous drainage lift out of your property.

Cycles On & Off Erratically

Damaged temperature sensors misread room heat, shutting off early or overworking the motor. We replace NTC thermistor sensors for accurate thermostat tracking.

Factory Specification Matching

9 Core AC Component Replacement Capabilities

We carry common high-failure parts directly in our service vans for fast, single-visit component replacements across Makati and Taguig.

STEP 01 β€’ COMPRESSOR

Compressor Diagnostics & Replacement

When the compressor fails, your unit runs without producing cold air. We test internal windings, source brand-matched replacement compressors, vacuum the lines, and run stress tests.

STEP 02 β€’ MOTORS

Fan Motor Replacement

Weak airflow or screeching noises stem from failing indoor blower or outdoor condenser motors. We replace worn fan motors with exact voltage and RPM spec matches.

STEP 03 β€’ ELECTRONICS

PCB Control Board Repair & Swap

Error codes, unresponsive remotes, or sudden shutoffs point to a failed PCB board. We run circuit diagnostics to repair minor board faults or install factory-compatible replacement modules.

STEP 04 β€’ ELECTRICAL

Dual-Run Capacitor Replacement

A weak capacitor prevents your compressor and fan motor from starting up. We test microfarad ratings and replace worn capacitors on the spot to protect your compressor from burning out.

STEP 05 β€’ DRAINAGE

Automatic Drain Pump Replacement

Water pooling inside the unit or leaking to your ceiling? A failed drain pump cannot move water out. We replace faulty pumps, clear lines, and confirm proper drainage flow.

STEP 06 β€’ SENSORS

Thermostat & NTC Sensor Calibration

Wrong temperature readings or erratic cycling indicate a faulty sensor. We test thermistor resistance levels and replace faulty sensors during the same visit.

STEP 07 β€’ VALVES

Thermal Expansion Valve (TXV) Fix

Coil icing and pressure problems stem from a jammed expansion valve. We install the correct replacement valve, recharge to specification, and restore Freon flow.

STEP 08 β€’ EVAPORATOR

Indoor Evaporator Coil Replacement

Corroded or leaking evaporator coils cannot absorb heat. We replace indoor coils with brand-matched aluminum or copper units and pressure-test for zero leaks.

STEP 09 β€’ CONDENSER

Outdoor Condenser Coil Replacement

Overheating outdoor units caused by severely damaged condenser fins require full coil replacement. We swap coils, pressure-test, and verify powerful heat release.

Off-Spec Salvage vs Sterling Air OEM Genuine

Why brand-matched parts are essential for lasting cooling performance.

COMPONENT FEATURE
CHEAP OFF-SPEC PARTS
STERLING AIR FACTORY OEM PARTS RECOMMENDED
Microfarad / Voltage Spec
βœ•
Inaccurate capacitance burns out motor windings
βœ“
Exact microfarad & voltage rating matching
PCB Board Compatibility
βœ•
Generic boards cause erratic thermostat cycling
βœ“
Factory-compatible brand circuit board modules
Compressor Sourcing
βœ•
Second-hand salvage or re-stamped units
βœ“
Brand-new OEM specification compressors
Installation Workmanship
βœ•
Quick tape patches and loose electrical terminals
βœ“
Soldered joints, heat shrink insulation & torque specs
Post-Service Warranty
βœ•
Zero backing when part fails 2 weeks later
βœ“
30-Day Parts & Labor Warranty on all installations

BULK & MULTI-UNIT COMPONENT MANAGEMENT

Bulk AC Parts Replacement & Sourcing for Makati & Taguig Properties

Managing multiple split-type, window-type, or ceiling cassette units across a BGC condo portfolio, residential complex, or corporate office in Legazpi Village?

Sterling Air provides turnkey component sourcing and replacement protocols tailored for property managers, landlords, and facility admins.

We handle thorough diagnostic audits, genuine factory part sourcing, multi-unit component swaps, and high-precision testing with zero disruption to your property or operations.

βœ” Factory-Matched OEM Parts β€” High-grade capacitors, PCB boards, motors, and compressors matched to unit specs
βœ” Priority Multi-Unit Dispatch β€” Flexible scheduling including after-hours work windows for offices & condos
βœ” End-to-End Admin Clearance β€” Work permits, gate passes, and insurance documentation handled by us
βœ” 30-Day Parts & Labor Warranty β€” Comprehensive diagnostic stress-test reports and guaranteed warranty backing